Skip to main content

Insertion Flow Probe Meter Specification Chart

Options

Wetted Materials

316SS (Std.). Hastelloy-C, Tantalum, and others are available by request

Process Connections

1/2″, 3/4″ & 1″ MNPT Compression Fitting, Insert Flange, Tri- Clover, Welded Union
Hot Tap Assembly with 1″ Full Port Ball Valve
Mechanical Retractor System

Probe Size (OD)

1⁄2″ or 3⁄4″ Std. 1″, 11⁄2″, 2″ Application Dependent.

Probe Length

9″, 14″, 25″ (Std.). Custom Lengths Available

Protective Coatings Available

Teflon, Others

Standard Installation

10 pipe diameters before meter install point and 5 pipe diame- ters after meter without any piping changes. If those condi- tions cannot be met, Thermal Instrument , in some instances, can simulate piping in order to calibrate to installation condi- tions.

Engineering Specifications

Accuracy

±0.50% of Full Scale**

Repeatability

± .20% of Rate

Turndown

10:1 Std. up to 1000:1 Application Dependent

Temperature Span

Operating Temperature ± 50°F

Response Time

Gas —1 Second ; Liquids < 500ms

Flowrates

Gas 40—20,000 SFPM
Liquid 0—10 FPS

Pressure Rating

Varies by Application & Process Connection

Temperature

-40—350 °F (Std), -40—176°C (Std.)

** Note—Accuracy of Meter Reading based on Air and meeting all piping conditions

Transmitter Specifications (Integral Or Remote)

Model Shown

9500P

Display

8 Digit Flow Rate & Total Flow Rate

Power

120 / 240 VAC, 50/60 Hz
24 VDC, 1 Amp

Outputs

4-20 MADC Flow (Std.)
4-20 MADC Temperature (Opt.)

Optional Outputs

0-5 VDC, 0-10 VDC Optional
Pulse Output (Opt.)
Modbus RS 485
Hart Communication

Remote

Up to 2000’. Signal Cable – 18 Gauge, 2 Pair with shield

Communication via Micro USB & 4 Button Menu System (Opt.)

Adjustable Variables

Filter Factor, Flow Full Scale, Flow Factor, Pipe ID, Zero Cutoff %, Modbus ID Value

Enclosure Specifications

Cast Aluminum, Epoxy painted with window

Connection

3⁄4″ FNPT Power & Signal

Ratings

Nema 4, Explosion Proof, Class 1, Div 1 Groups B, C, D Weatherproof

Temperature

Ambient –13 to 140°F (-25 to 60°C)
Storage –40 to 158°F (-40 to 70°C)