Skip to main content

Insertion Flow Probe Meter Specification Chart

Probe Specification

Model # 62-9

Pipe / Line Size:

2½” SCH 40 to Unlimited

Flow Measuring Capability:

Gas:

40 to 15,000 SFPM

Liquid:

.01 to 15 Feet per Second

Temperature Range:

Fahrenheit:

-20 to 350

Celsius:

-28 to 162

ENGINEERING SPECIFICATIONS

Mounting:

Integral to the Flow Transducer

Accuracy: +/- .50% of Full Scale, [or 2.0% of reading whichever is better. Full Scale over the calibrated range. [Process fluid temperature span +/- 50°F]

Remote to 4000 ft., Wall or Frame mount

Repeatability: +/- 0.2 % of Rate

Signal Cable for Remote Design: 18 gauge, 2 pair with cable shield. Maximum distance, 4000 ft.

Response Time:

MODEL NUMBERING SYSTEM:

Gases: 1 to 2 sec. Typical

Base Model: = 9500

Liquids: Less than 500ms

Pressure Rating:

Electronics Mounting:

0 – 1200 psig (Std)

I = Integral Mount

0 – 10000 psig Dependent on meter size

R = Remote Mount

F = Fluid

Flow Rates:

G = Gas

Gas: 40 to 86,000 SFPM

L = Liquid

Liquid: .02 to 20 FPS

Note: maximum determined by pipe capacity

Flow Range: 100:1 Std. Multiple ranges available

Material:

316SS = STD

Calibrated Temperature Range:

Corrosion Resistant Materials available by request: Hastelloy C, Monel, Inconel, Tantalum, and Carpenter 20

Gas: -20 F to 350 F (-28°C to 162°C )STD.

Available Coatings: Carbide, Fluorocarbon , Teflon, and Sulfinert

[-20°F to 600°F] (-28°C to 315°C) Optional)

Process Connection:

Liquid: -20F to 350F (-28°C to 162°C ) STD.

PG = Packing Gland (Std.)

[ -20°F to 500°F](-28°C to 260°C) Optional

FLG-150 =150# RF Flange (Std.Van stone)

TC = Triclover

Wetted Materials: 316SS (STD). Consult the factory for other material requirements

FLG-Other = Consult Factory

Other = Consult Factory

Connections: Flange, Packing Gland, Triclover, Hot Tap

Power:

Calibration Temperature Capability: -20°F to 600°F(-29°C to 315°C)

24 = 22-26 VDC, 1 AMP. 4 WIRE

120 = 120VAC, 1/2 AMP, 50/60 HZ (STD.)

MICRO-CONTROLLER SPECIFICATIONS:

240 = 240VAC 50/60 HZ

16 BIT A/D

Output Signals:

Displays: Bright LED 2 Line 8 digit

(Select One**)

Capable of displaying Current Flowrate and Total Flow (Optional)

0/5 = 0-5 VDC**

0/10 = 0-10 VDC**

Communicator:

4/20 = 4-20 mADC** into 750 ohms, Isolated std, Self Powered

Interface: RS-232 via Ribbon Connector

4/20T = Opt Process Fluid Temp. 4-20mA Self Powered

Baud Rate: 9600

Other = Consult Factory

Filter Factor

Flow Full Scale

Display: (Optional)

Flow Rate Decimal Point

ND = No Display

Flow Totalizer Decimal Point

D = Flowrate Display, 8 Digit

Flow Totalizer Flowrate Ratio

8T = Totalizer

D/8T = Flowrate and Total Display, 8 digit

Power:

120/240 vat, 50/60 Hz.

Signal Cable for Remote Design: SC25 = 25 FT Supplied with remote configuration

24VDC, 1 Amp (Factory Set)

Electrical Connections:3/4” FNPT Power & Signal

Enclosure: Cast Aluminum, Epoxy Painted

Environmental Ratings:

Housing: Explosion Proof, Class 1, Div. 1, Groups, B, C D

Weatherproof: Nema 4

Ambient Temperature: -25 to 60 C (-13 to 140 F)

Storage Temperature: -40 to 70 C ( -40 to 158F )